[...]Reliable pre-treatment for septic sludge Wherever wastewater is not fed to a sewage treatment plant via the sewer system, but is treated decentrally, septic sludge is produced. This septic sludge collects either in simple septic tanks or in more modern small wastewater treatment plants and must be removed at regular intervals to be treated in a central plant. Where possible, this is done at a centralized wastewater treatment plant with sufficient surplus capacity; but where such a plant is not available nearby, a separate onsite plant for the complete treatment of septic sludge can also be built. Septic[...]
[...]Ingolstadt, Germany Two HUBER belt dryers BT were put into operation on STP Ingolstadt in August 2005. The installed total dryer surface is 160 m² which is the same as that of our new dryer type BT 16. The scope of supply of HUBER SE included not only the drying plants but also the sludge bunkers and thick sludge pumps. The exhaust air treatment system has already been installed. Figure 2 shows the complete plant. The special feature of sewage sludge drying on STP Ingolstadt is that the drying process takes place on a very low temperature level. Warm water with a temperature of 53 °C is available[...]
[...]Products and solutions for the safe operation of sewer systems and the protection of our environment Only with a functioning sewer network can secure wastewater disposal be ensured that meets both water protection and flood protection requirements. Combined sewers carry the wastewater together with the rainwater that accumulates on paved surfaces (roofs, roads, etc.). In a separate sewer system, wastewater and stormwater are collected separately. The disadvantage of separate sewer systems is higher investment costs, the advantage is that less wastewater has to be treated in the sewage treatment[...]
[...]Combined Sewerage and Stormwater Treatment Protection of water bodies from polluted rainwater The advanced treatment of combined and stormwater in wastewater transportation systems is a main issue with regard to sustainable environmental and water protection. The building of new wastewater treatment plants and the upgrading or refurbishing continuous wastewater discharges has significantly increased the quality of many watercourses. Nevertheless, despite all efforts, ecological deficits still exist. Some of the problems are caused in the discharges of combined and separated sewers during storm [...]
[...]Access door for buildings in the field of potable water supply equipped with a burglar alarm system The security door is burglar and attack-resistant, certified to DIN EN 1627, resistance class RC3. It is ready for installation, double-skinned, and entirely constructed from 1.4307 stainless steel (AISI 304 L). The door features a double rubber seal, with the door and frame closing flush. It opens outward in the escape direction. Sound insulation: 34/29 dB. Security class RC3 is recommended by the criminal investigation department if the building is additionally secured by means of a burglar [...]
[...]Access door for buildings in the field of potable water supply without a burglar alarm system Security class RC4 is recommended by the criminal investigation department if the building is not secured by means of a burglar alarm system. The security door is burglar and attack-resistant, certified to DIN EN 1627, resistance class RC4. It is a single-leaf, double-skinned door, fully constructed from 1.4307 stainless steel (AISI 304 L), featuring a double rubber seal. The door and frame close flush, and the door opens outward in the escape direction. The door provides sound insulation with a rating[...]
[...]Security door, burglar and attack proof, certified to security of DIN EN 1627, resistance class RC3, ready for installation, single-leaf, double skinned, watertight up to 1.2 m WG, completely made from 1.4307 (AISI 304 L) stainless steel, with double rubber seal, the door opening to the outside (in escape direction). Door with injected CFCs-free polyurethane hard foam insulation. Longitudinally ground surface finish, with rubber seal. The closed door engaging flush with the frame by means of solid anchor bolts engaging in the frame for four-point locking. Fastened to the frame with stable, [...]
[...]Access door for buildings in the field of potable water supply and wastewater disposal with average security requirements. Door, ready for installation , single door, double skinned, completely made from 1.4307 (AISI 304 L) stainless steel, with double rubber seal, the door and frame closing flush, the door opening to the outside (in escape direction). Door leaf , skin: 1 mm, 2 in. / 55 mm thick, with injected CFCs-free polyurethane hard foam insulation, longitudinally ground surface finish, with rubber seal. Fastened to the frame with stable maintenance-free hinge plates. Mortise dead lock [...]
[...]Access door for water chambers, ready for installation, single door, double skinned Completely made from 1.4404 stainless steel (AISI 316 L), with double rubber seal. The door and frame closing flush, the door opening to the outside (in escape direction). Door leaf, skin: 1 mm , 2 in. / 55 mm thick, with injected CFCs-free polyurethane hard foam insulation, longitudinally ground surface finish, door seal certified to KTW and DVGW W270 standards. Fastened to the frame with stable maintenance-free hinge plates. Mortise dead lock completely made from stainless steel according to DIN 18251, class 3,[...]
[...]Access door for buildings in potable water supply where chlorine gas is stored or used Chlorine room door, pre-assembled and ready for installation, single door, double-skinned, constructed entirely from 1.4404 (AISI 316 L) stainless steel featuring a double rubber seal. The door and frame close flush, and the door opens outward (in direction of escape), compliant with OSHA standards. Door with a 1 mm skin, 2 in. / 55 mm thickness, featuring injected CFCs-free polyurethane hard foam insulation, a longitudinally ground surface finish, door inside lacquered in RAL 9006 (stainless steel look), [...]