[...]Safety access ladder with guard rail, with design certification and CE marking, in accordance with DIN EN 14396, made of 1.4307 (AISI 304 L) stainless steel. Designed to attach an insertable entrance aid. In accordance with UVV regulations ladders with 3 m or 5 m a height of all must be equipped with devices that protect personnel against falls from a height. In accordance with DIN EN 14396, made of 1.4307 (AISI 304 L) stainless steel, designed to attach an insertable entrance aid. Handles made of special profile of high rigidity (57 x 25 x 2.5 mm), covered with PVC caps. Rungs made of U-profile[...]
[...]Safety climbing device, with design certification and CE marking, in accordance with DIN EN 14396, made of 1.4307 (AISI 304 L) stainless steel. In accordance with UVV regulations ladders with 3 m or 5 m a height of all must be equipped with devices that protect personnel against falls from a height, in accordance with DIN EN 14396, made of 1.4307 (AISI 304 L) stainless steel. The handle in the middle is made as a safety guard rail, with bottom and top trip gear, which can only be undone by hand, U-profile climbing rungs with perforated surface, 30 mm, slip resistance R 13 and lateral slipping limits[...]
[...]Increasing operational safety for pumping stations Pumps and lifting units are used where wastewater needs to be lifted to a higher level so that it can be passed further on by gravity. However, the solids contained in the wastewater (coarse materials, foreign matter, fibres) often lead to a failure of the units used, as they cause operational downtimes due to clogging and blockages. Labour-intensive manual cleaning is required to restore the function of the units or, in the worst case, they even need to be replaced. To ensure trouble-free and reliable operation of a pumping or lift station, the [...]
[...]Reducing screenings volume and disposal costs The screenings from municipal wastewater treatment mainly consist of household waste-like materials, faeces, paper and mineral particles. The screenings volume depends on the aperture size of the screening system. The solids content of municipal, untreated screenings varies from 5 – 20 %, depending on the type of screen. The organics contained in the screenings amount on average to approx. 90 % of the dry residue [DR]. The objectives of screenings treatment are: Dewatering of the screenings and thus reduction of screenings weight and volume. This [...]
[...]Reliable water intake systems for open waters HUBER offers its customers a comprehensive portfolio of innovative mechanical treatment systems for water intakes, for both new plants and the modernisation of existing plants. The systems are customised to the individual needs and the required water quality of each project. Customers benefit from our decades of expertise for particularly stable and reliable fully automated machines with the best hydraulic properties for maximum separation rates. Depending on the application and installation situation, our solutions include multi-stage screens and screening[...]
[...]Seefelden, Germany The Seefelden sewage treatment plant in the Überlinger See wastewater association on Lake Constance with 70,000 population equivalents is to receive advanced wastewater treatment to remove trace substances. The heart of the new treatment stage will be a process combination of ozonation and activated carbon filtration – on a technical scale that has never been realized in Germany before. For this showcase project, HUBER will supply 24 Active Carbon Filters CONTIFLOW® GAK for biological post-filtration and adsorption of trace substances after the ozonation stage. Investment [...]
[...]Sludge Acceptance Plants Sewage sludge screens and septage receiving stations for efficient acceptance and treatment of septic sludges HUBER Sludge Acceptance Plant ROTAMAT® Ro3.1 Sludge Acceptance Plants | Machines for Sludge Screening HUBER Sludge Acceptance Plant ROTAMAT® Ro3.3 Sludge Acceptance Plants HUBER Sludge Acceptance Plant RotaShield® Sludge Acceptance Plants | Machines for Sludge Screening Efficient system solutions and technologies for efficient septic sludge treatment For any type of septic sludge Reliable separation of all disturbing material Dependable and reliable in [...]
[...]Reliable pre-treatment for septic sludge Wherever wastewater is not fed to a sewage treatment plant via the sewer system, but is treated decentrally, septic sludge is produced. This septic sludge collects either in simple septic tanks or in more modern small wastewater treatment plants and must be removed at regular intervals to be treated in a central plant. Where possible, this is done at a centralized wastewater treatment plant with sufficient surplus capacity; but where such a plant is not available nearby, a separate on-site plant for the complete treatment of septic sludge can also be built. [...]
[...]Products and solutions for the safe operation of sewer systems and the protection of our environment Only with a functioning sewer network can secure wastewater disposal be ensured that meets both water protection and flood protection requirements. Combined sewers carry the wastewater together with the rainwater that accumulates on paved surfaces (roofs, roads, etc.). In a separate sewer system, wastewater and stormwater are collected separately. The disadvantage of separate sewer systems is higher investment costs, the advantage is that less wastewater has to be treated in the sewage treatment[...]